Blank in pmpsvc

Product:
Planning Analytics Local 2.0.9.18
TM1_version=TM1-AW64-ML-RTM-11.0.918.3-0
Microsoft Windows 2019 server

Problem:

After upgrade of Planning Analytics Local installation (PAL), the TM1 App Web is not showing the applications.

Suggested Solution:

Stop the service IBM Cognos TM1

Go to folder D:\Program Files\ibm\cognos\tm1_64\webapps\pmpsvc\WEB-INF\configuration

Rename fpmsvc_config.xml to fpmsvc_config.xml.old.txt

Rename fpmsvc_config.xml.new to fpmsvc_config.xml

Copy the lines between, the tm1 markers, that contain the name of the applications:

<tm1>
 </tm1>

from the file fpmsvc_config.xml.old.txt to the file fpmsvc_config.xml

Now the applications and gateway uri should be listed in the new file.

Start the service IBM Cognos TM1

More information: