Product:
Cognos Controller 10.3 fix pack 1 =
(IBM Cognos Controller Version 10.3.1.43
Integration Version 10.3.1.19
Install/Updater Kit Version 10.3.1.29)
Microsoft Windows 2012 R2 server
Microsoft SQL 2014 database

Problem:
After upgrade to new version of Cognos Controller 10.3 when you go into the new IBM Cognos Controller Financial Analytics Publisher client (FAP) and click edit on a Source that have log level “detailed” you get a error message.

Other controller database “sources” that are listed work fine to be open by EDIT button in FAP client.

Error message:

See the end of this message for details on invoking

just-in-time (JIT) debugging instead of this dialog box.

 

************** Exception Text **************

System.ArgumentOutOfRangeException: InvalidArgument=Value of ‘3’ is not valid for ‘SelectedIndex’.

Parameter name: SelectedIndex

at System.Windows.Forms.ComboBox.set_SelectedIndex(Int32 value)

at FAPClient.frmEditSource.frmEditSource_Load(Object sender, EventArgs e)

at System.Windows.Forms.Form.OnLoad(EventArgs e)

at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)

at System.Windows.Forms.Control.CreateControl()

at System.Windows.Forms.Control.WmShowWindow(Message& m)

at System.Windows.Forms.Control.WndProc(Message& m)

at System.Windows.Forms.Form.WndProc(Message& m)

at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

 

 

************** Loaded Assemblies **************

mscorlib

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.NET/Framework64/v4.0.30319/mscorlib.dll

—————————————-

FAPClient

Assembly Version: 10.3.1.19

Win32 Version: 10.3.1.19

CodeBase: file:///E:/Program%20Files/ibm/cognos/ccr_64/webcontent/ccr/FAPClient.exe

—————————————-

Microsoft.VisualBasic

Assembly Version: 10.0.0.0

Win32 Version: 12.0.20806.33440 built by: FX45W81RTMREL

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/Microsoft.VisualBasic/v4.0_10.0.0.0__b03f5f7f11d50a3a/Microsoft.VisualBasic.dll

—————————————-

System

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System/v4.0_4.0.0.0__b77a5c561934e089/System.dll

—————————————-

System.Core

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Core/v4.0_4.0.0.0__b77a5c561934e089/System.Core.dll

—————————————-

System.Windows.Forms

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Windows.Forms/v4.0_4.0.0.0__b77a5c561934e089/System.Windows.Forms.dll

—————————————-

System.Drawing

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Drawing/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Drawing.dll

—————————————-

System.Runtime.Remoting

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Runtime.Remoting/v4.0_4.0.0.0__b77a5c561934e089/System.Runtime.Remoting.dll

—————————————-

C1.Win.C1FlexGrid.4

Assembly Version: 4.0.20153.110

Win32 Version: 4.0.20153.110

CodeBase: file:///E:/Program%20Files/ibm/cognos/ccr_64/webcontent/ccr/C1.Win.C1FlexGrid.4.DLL

—————————————-

System.Xml

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Xml/v4.0_4.0.0.0__b77a5c561934e089/System.Xml.dll

—————————————-

System.Configuration

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Configuration/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Configuration.dll

—————————————-

System.Data

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36372 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_64/System.Data/v4.0_4.0.0.0__b77a5c561934e089/System.Data.dll

—————————————-

System.Numerics

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Numerics/v4.0_4.0.0.0__b77a5c561934e089/System.Numerics.dll

—————————————-

System.Transactions

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_64/System.Transactions/v4.0_4.0.0.0__b77a5c561934e089/System.Transactions.dll

—————————————-

System.EnterpriseServices

Assembly Version: 4.0.0.0

Win32 Version: 4.0.30319.33440 built by: FX45W81RTMREL

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_64/System.EnterpriseServices/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.EnterpriseServices.dll

—————————————-

Microsoft.GeneratedCode

Assembly Version: 1.0.0.0

Win32 Version: 4.0.30319.36366 built by: FX452RTMLDR

CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Xml/v4.0_4.0.0.0__b77a5c561934e089/System.Xml.dll

—————————————-

 

************** JIT Debugging **************

To enable just-in-time (JIT) debugging, the .config file for this

application or computer (machine.config) must have the

jitDebugging value set in the system.windows.forms section.

The application must also be compiled with debugging

enabled.

 

For example:

 

<configuration>

<system.windows.forms jitDebugging=”true” />

</configuration>

 

When JIT debugging is enabled, any unhandled exception

will be sent to the JIT debugger registered on the computer

rather than be handled by this dialog box.

Possible workaround:
Looks like the new version of FAP does not support detail logging.
In old version of Controller FAP this setting would show DEBUG log level. Please ensure you take a backup of the SQL database before you do any changes in it. If this does not work, you can restore the Controller FAP database.
So go into Microsoft SQL Server Management Studio.
Connect to the database server there you have your controllerfap database.
Select you ControllerFap database and on table dbo.NRTR_SOURCE right click and select Edit Top 200 Rows.
Far to the right you have column “LogLevel” – here there is a value of 40, change that to 30, for the source you get the error.
Exit out and check that your update is there with SQL command:

SELECT TOP 100 [Name]
,[Status]
,[Type]
,[UserName]
,[Password]
,[NRTRPurgeDate]
,[NRTRPurgeSecNum]
,[NRTRPurgeTextSecNum]
,[CCRMoveIndex]
,[CCRTextMoveIndex]
,[CCRDBUrl]
,[LogLevel]
,[Info]
,[Interval]
,[IntervalCounter]
FROM [ControllerFAP].[dbo].[NRTR_SOURCE]

Now go into your FAP client and on the source tab
mark the name of the data source who have detailed loglevel and click on Edit button.
You should now get into the edit dialog without errors.

The loglevel in “edit source..” show High, instead of Detail as listed.
You can update the server value.
The port number is missing do, so you may need to add it 1433.
Click on Test Connection to see that it works.
Click Save.

You have now updated the FAP to work with the new ControllerFAP database on the new SQL server.

Product:
Cognos Tm1 10.2.2
Microsoft Windows 2012 R2 server

Problem:
Can not connect to TM1 server from other computer, but it works fine direct on the TM1 server to connect from TM1 architect.

Possible Solution:
The Windows firewall is blocking the connection.
This looks like TM1 architect is not responding for a long time and then you are not seeing a list of TM1 applications.

You need port 5498 open to get contact with the TM1 admin service from the TM1 architect client.
You need the TM1 applications port (e.g. 12345) to connect to the application from TM1 architect client.

Go to control panel on the TM1 windows server
Click on Windows firewall
Click on Advance settings
Select inbound rules and click on New Rule on the left
Select Port and click next
Enter list of ports at Specific local ports
(e.g. 80,9300,9080,9510,5495,5498,12345,12346)
ensure you use comma between the port numbers.
click Next
Select Allow the connection and click next
Keep all marked for where the rule apply and click next
Set a name (e.g. cognos) and click finish

Now test again from you remote computer where TM1 architect are installed.

Cognos Controller 10.3 need this ports;
80,9300,9080
Cognos BI 10.2.2 need this ports;
80,9300,9362 ,25,389,1433
Cognos Tm1 10.2.2 need this ports;
80,9510,9513,5495,5498,12345,12346 + your TM1 applications ports.

If you have all products, then you need to open all this ports between the Cognos Servers.
You need also open port for database connections, like 1433 for Microsoft SQL server and 389 for Active Directory contact.
Port 25 is used for sending mail from Cognos BI.

No port over 65535 is allowed to be configured in Windows firewall.
TM1 sample application Proven_techniques uses port 83333 as default and need therefor to be changed to port 13333.
PortNumber=12345 is for planning sample application.
PortNumber=12346 is for SDATA app, that you use for opsconsole as default login.
PortNumber=9510 is used by CAFE and PM.

You can in TM1S.CFG set a client port number for each tm1 application. Should be used if you have firewalls between server and client computer, or client is a citrix server. This number need also to be open in the firewall.
# Note: Be sure to assign unique port numbers for the server and client message ports. If you have two servers running on the same machine with the same port number, the message activity may cause a system failure.
ClientMessagePortNumber=32345

Best is if you keep a notepad txt file on your server where you enter each TM1 PortNumber and ClientMessagePortNumber, so you easy can see that you not by mistake reuse the same number.

More information:
http://www-01.ibm.com/support/docview.wss?uid=swg21459257

Product:
Cognos Controller 10.3
Microsoft Windows 2012 R2 server

Problem:
When starting the Cognos Controller client for the first time in a new installation, you get a error like this:
An error occurred while trying to access the server.
Details give:
The request failed with HTTP status 405: Method Not Allowed.
at System.Web.Services.Protocols.SoapHttpClientProtocol.ReadResponse(SoapClientMessage message, WebResponse response, Stream responseStream, Boolean asyncCall)
at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters)
at Cognos.Controller.ControllerSoapHttpClientProtocol.Invoke(String methodname, Object[] parameters)
at Cognos.Controller.Proxy.Light.WSLight.CheckServerConnection(String sGuid, String sUser)
at Cognos.Controller.Direct.ServerInfoD.CheckServerConnection()
at CCR.AppContext.CheckConnectionToServer()

If you start Internet explorer and surf to
http://APPSERVER:80/ibmcognos/controllerServer/ccrws.asmx
you get a HTTP error 404

Solution:
Ensure that on the Cognos Controller server you have installed windows roles for .NET extensibility 4.5 and ASP.NET 3.5 and ASP.NET 4.5 under Application Development for IIS server role.

This show some of what need to be in the Windows server to make Cognos Controller work:
http://www-01.ibm.com/support/docview.wss?uid=swg21986254

More information:
http://www-01.ibm.com/support/docview.wss?uid=swg21653361

Product:
Cognos BI 10.2.2
Microsoft Windows 2012 R2 server

Problem:
When starting the Cognos BI service, it takes long time and we get a error.
[Start Service]
[ ERROR ] CFG-ERR-0106 IBM Cognos Configuration did not receive a response from the IBM Cognos service in the time allotted.
Check that IBM Cognos service is available and properly configured.

In this cbs_start_WebSphereLiberty.logfile the text is:
Wed Apr 26 15:13:27 2017 ERROR t[1a08] CBSSocketCommand failed to connect, CAM error: -12CAM-CRP-0026 The underlying socket: ‘10.151.38.35:9300’ returned an error.10061Could not connect the socket, errno: 0x274d(10061)
Wed Apr 26 15:13:29 2017 INFO t[1a08] CBSBootstrapService testReadyByPingingWin – child processes are not ready, stop trying.

Solution:
The windows service account that run the IBM Cognos service does not have enough rights in the Windows box. IT department have a process that every night they remove accounts direct from the local administrator group. This service account was in there the other day when system was installed. But as of removing it then the Cognos BI process not successfully started.

Ensure that the Cognos BI service account has needed rights on the server.

Other causes:
http://www-01.ibm.com/support/docview.wss?uid=swg21646350

Product:
Cognos TM1 architect 10.2.2
Microsoft Windows 2012 R2 standard server

Problem:
Login dialog when you start TM1 architect, and you have configured it to be SSO to the Cognos BI Cognos Connection.
If you surf to http://cognosBIserver.domain.com/ibmcognos you are automatically logged in.

Login dialog titled : Windows Security

tm1a.exe connecting to biservername.domain.com

User name

Password

Solution:
On the computer where you start TM1 architect, go to control panel and internet options.
Go to Security tab.
Select Local Intranet and click on sites button.
Click on advance button.
Enter the URL to the Cognos BI server;
http://biservername.domain.com
Click on Add button.
Click Close.
Click OK.

Restart TM1 architect, and see if the SSO are working.

For SSO to work with TM1 clients and Cognos BI the CAM authentication Bi server must be in local intranet or trusted intranet zone of Internet Explorer on client computer.

Product:
Cognos TM1 10.2.2
Microsoft Windows 2012 R2 standard server

Problem:
When inside TM1 architect try to add a new user (clients – add new client) you get a error message about the CAM. The dialog will not show up.

Possible solution:
The value in the file tm1p.ini for that user is not updated with a URL to the cognos bi server.

You update the TM1S.CFG file for the TM1 server – but this change is not copied to the TM1 architect users.

IntegratedSecurityMode=2
ServerCAMURI=http://biservername:9300/p2pd/servlet/dispatch
ClientCAMURI=http://biservername.domain.com:80/ibmcognos/cgi-bin/cognosisapi.dll
ClientPingCAMPassport=900
CAMPortalVariableFile=portal\variables_TM1.xml

Only new TM1 architect users will get value from file E:\Program Files\ibm\cognos\tm1_64\bin64\tm1p.ini.

You need to close TM1 architect and update this file
C:\Users\%username%\AppData\Roaming\Applix\TM1\tm1p.ini in notepad.

Add values for
AllowImportCAMClients = T
CognosGatewayURI = http://biservername.domain.com:80/ibmcognos/cgi-bin/cognosisapi.dll

save the tm1p.ini file and start the TM1 architect program again.

Product:
Cognos Controller 10.3
Oracle 12c database
Microsoft Windows 2008 R2 Server

Problem:
Standard Error generated when running Multi Period Locking report, and you have not selected a “Use Filter”.

Error message:
“Number: 5
Source: FrangoDirect.PerLockHandler.SelectMultiPerLocks#System.Web.Services
Description: System.Web.Services.Protocols.SoapException:
Server was unable to process request. —> System.InvalidCastException:
Conversion from type ‘DBNull’ to type ‘Date’ is not valid……..”

Possible Solution:
Set a Selected filter when using “Multi Period Locking” and run the report for a specific period.

This is different behavior since Controller version 10.1.1 where this did not give a error.

Other workaround is to enter a date in the column for date in the “Define Submission” dialog in Cognos Controller for all rows.

More Information:
http://www-01.ibm.com/support/docview.wss?uid=swg21977555

Product:
Cognos Controller 10.3
Oracle 12c database
Microsoft Windows 2008 R2 server

Problem:
Got error in Cognos Controller client when doing a database optimization or run a Reconcile – Intercompany Balances.

Error message:
An unexpected error has occurred

System.ArgumentException: System.Web.Services.Protocols.SoapException: Server was unable to process request. —> System.Exception: fgsql c:\program files\ibm\cognos\ccr_64\server\progs\fgsql.prg Error in line 324 Connection handle is invalid. 1466……

Solution:
Only the 64 bit oracle drivers are installed. Install the 32 bit oracle drivers on the Cognos Controller server.
The small calculations component is still 32 bit in the 64 bit version of Cognos Controller. Therefor you must have both 64 bit and 32 bit database drivers installed on the Controller servers.

More information:
http://www-01.ibm.com/support/docview.wss?uid=swg21365329
http://www-01.ibm.com/support/docview.wss?uid=swg21677791
http://www-01.ibm.com/support/docview.wss?uid=swg21676449

Product:
Cognos Controller 10.3
Microsoft Windows 2012 server

Problem:
At start of cognos controller client, from a new installation, you get a error message.

Error message:
An error occurred while trying to access the server.
http://localhost/ibmcognos/controllerserver

The request failed with HTTP status 404: Not Found.
at System.Web.Services.Protocols.SoapHttpClientProtocol.ReadResponse(SoapClientMessage message, WebResponse response, Stream responseStream, Boolean asyncCall)
at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters)
at Cognos.Controller.ControllerSoapHttpClientProtocol.Invoke(String methodname, Object[] parameters)
at Cognos.Controller.Proxy.Light.WSLight.CheckServerConnection(String sGuid, String sUser)
at Cognos.Controller.Direct.ServerInfoD.CheckServerConnection()
at CCR.AppContext.CheckConnectionToServer()

Solution:
The app folder in IIS for controllerserver was misspelled, recreate the application controllerserver in IIS manager.

Product:
Cognos Analytics 11.0.6
Microsoft Windows 2012 server
DB2 11.1.1 database server

Problem:
How create a content store in DB2?

Solution:
Install Cognos Analytics 11 on the windows server.
Install DB2 11 on the database server, ensure the local administrator is administrator on the db2 database to.

From the DB2 server copy the jar files needed from folder
C:\Program Files\IBM\SQLLIB\java. Place the two files
d2jcc_license_cu.jar
db2jcc4.jar
in folder c:\program files\ibm\cognos\analytics\drivers on the Cognos BI server.

Start Cognos Configuration and setup up the values for the environment.
On the Content Store tab enter the values for the DB2:
database server and port number: Enter ipadress:50000
User id and password: Enter the namn and password you want the schema to have.
Database name: Enter the name of the database you want it to have.

Click save.
Right click on Content store and select “Generate DDL”.
This will create a SQL script you should run on the DB2 server to create the needed database.
Copy the file C:/Program Files/ibm/cognos/analytics/configuration/schemas/content/db2/createDb.sql to the DB2 server.
Place the file in folder c:\install.

On the DB2 server login as Windows administrator.
Start a DB2 Command Windows – Administrator.
Enter this command:
db2 -tvf c:\install\createDb.sql

This will run the steps to create the content store database.
Will be similar to this;

CREATE DATABASE cm AUTOMATIC STORAGE YES ALIAS cm USING CODESET UTF-8 TERRITORY
US COLLATE USING SYSTEM PAGESIZE 8192
DB20000I Kommandot CREATE DATABASE har utförts.
CHANGE DATABASE cm COMMENT WITH ‘IBM Cognos Content Store’
DB20000I Kommandot CHANGE DATABASE COMMENT har utförts.
CONNECT TO cm
Information om databasanslutning
Databasserver = DB2/NT64 11.1.1.1
SQL-användar-ID = ADMINIST…
Lokalt databasalias = CM
UPDATE DATABASE CONFIGURATION USING APPLHEAPSZ 1024 DEFERRED
DB20000I Kommandot UPDATE DATABASE CONFIGURATION har utförts.
UPDATE DATABASE CONFIGURATION USING LOCKTIMEOUT 240 DEFERRED
DB20000I Kommandot UPDATE DATABASE CONFIGURATION har utförts.
CONNECT RESET
DB20000I Kommandot SQL har utförts.
CONNECT TO cm
Information om databasanslutning
Databasserver = DB2/NT64 11.1.1.1
SQL-användar-ID = ADMINIST…
Lokalt databasalias = CM
CREATE BUFFERPOOL cm_08KBP IMMEDIATE SIZE 1000 PAGESIZE 8K
DB20000I Kommandot SQL har utförts.
CREATE BUFFERPOOL cm_32KBP IMMEDIATE SIZE 1000 PAGESIZE 32K
DB20000I Kommandot SQL har utförts.
CONNECT RESET
DB20000I Kommandot SQL har utförts.
CONNECT TO cm
Information om databasanslutning
Databasserver = DB2/NT64 11.1.1.1
SQL-användar-ID = ADMINIST…
Lokalt databasalias = CM
CREATE SYSTEM TEMPORARY TABLESPACE TSN_SYS_cm IN DATABASE PARTITION GROUP IBMTEM
PGROUP PAGESIZE 32K BUFFERPOOL cm_32KBP
DB20000I Kommandot SQL har utförts.

When the database is finish created in DB2 server, then go to the Cognos Analytics 11 server and from inside Cognos Configuration click on START. This will start the Cognos BI service, and connect it to the database and create the tables needed.

The Cognos status will show this for a successful start;
[Launching a JVM using ‘Maximum memory in MB’]
Successfully launched a test JVM with the memory setting of ‘4096’. Note that this does not guarantee that the IBM Cognos service will start and run successfully.

To see which JVM options are based on this setting, view ibmcognos_location/bin64/bootstrap_wlp_.xml and see your JVM documentation for an explanation of those options.

[Archive Local File System Root]
Since the value is empty, the feature is disabled. There is nothing to test.

[Validate mail server properties.]
[ ERROR ] The mail server cannot be reached.

[Archive Local File System Root]
Since the value is empty, the feature is disabled. There is nothing to test.

[Start Service]
21:21:53, ‘LogService’, ‘StartService’, ‘Success’.
21:21:54, CAF-WRN-0010 CAF input validation enabled.
21:21:54, CAF-WRN-0021 CAF Third Party XSS checking disabled.
21:22:06, ”, ‘StartService’, ‘Success’.
21:22:08, CM-SYS-2057 Creating content store tables (schema version 7.0045).
21:22:16, CM-SYS-2215 A Content Manager internal PRECACHEINITACTIONS task started.
21:22:16, CM-SYS-2216 A Content Manager internal PRECACHEINITACTIONS task is complete.
21:22:16, CM-SYS-2093 The Content Manager cache initialization is complete. 1 objects loaded in 0,11 seconds.
21:22:17, CM-SYS-2216 A Content Manager internal POSTINITACTIONS task is complete.
21:22:16, CM-SYS-2215 A Content Manager internal POSTINITACTIONS task started.
21:22:39, CM-SYS-5159 Content Manager is running in active mode.
21:22:39, ‘ContentManagerService’, ‘StartService’, ‘Success’.
21:22:39, CM-SYS-2215 A Content Manager internal CMUPGRADESCRIPT task started.
21:22:41, DPR-DPR-1002 Successfully registered the dispatcher http://winca:9300/p2pd in Content Manager.
21:22:43, ‘idVizService’, ‘StartService’, ‘Success’.
21:23:25, ‘SACamService’, ‘StartService’, ‘Success’.
21:23:24, ‘camAsyncService’, ‘StartService’, ‘Success’.
21:23:27, ”, ‘Run’, ‘Run’.
21:23:34, ‘AnnotationService’, ‘StartService’, ‘ANN DB Validation successful.’.
21:23:34, ”, ‘Run’, ‘Run’.
21:23:36, ‘EventService’, ‘StartService’, ‘NC DB Validation successful.’.
21:23:43, ‘HumanTaskService’, ‘StartService’, ‘HTS DB Validation successful.’.
21:23:49, ‘zipiService’, ‘StartService’, ‘Success’.
21:23:49, ‘PDC’, ‘StartService’, ‘Success’.
21:23:50, ‘PresentationService’, ‘StartService’, ‘Success’.
21:23:51, Start a cgsLauncher because the start count 1 is larger than 0.
21:23:51, ‘BUX Service’, ‘StartService’, ‘Success’.
21:24:04, ‘RepositoryService’, ‘StartService’, ‘Success’.
21:24:04, ‘burstDistributionService’, ‘StartService’, ‘Success’.
21:24:04, ‘GraphicsService’, ‘StartService’, ‘Success’.
21:24:41, ‘QueryService’, ‘StartService’, ‘Success’.
21:24:48, ‘QueryService’, ‘StartService’, ‘Success’.
21:24:55,
21:24:55, ‘ReportService’, ‘StartService’, ‘Success’.
21:24:55, ‘visualisationGalleryService’, ‘StartService’, ‘Success’.
21:25:13, ‘camAsyncAA’, ‘StartService’, ‘Success’.
21:25:13, ‘ReportDataService’, ‘StartService’, ‘Success’.
21:25:14, ‘relationalMetadataService’, ‘StartService’, ‘Success’.
21:25:13, ‘Fragment Server Service’, ‘StartService’, ‘Success’.
21:25:14, ‘SACamSrvcInternal’, ‘StartService’, ‘Success’.
21:25:14, ‘QLSService’, ‘StartService’, ‘Success’.
21:25:13, ‘SystemService’, ‘StartService’, ‘Success’.
21:25:14, ‘BatchReportService’, ‘StartService’, ‘Success’.
21:25:13, ‘MobileService’, ‘StartService’, ‘Success’.
21:25:13, ‘ContentManagerCacheService’, ‘StartService’, ‘Success’.
21:25:13, ‘CacheService’, ‘StartService’, ‘Success’.
21:25:14, ‘QLSImportService’, ‘StartService’, ‘Success’.
21:25:14,
21:25:14, ‘SACamSrvc’, ‘StartService’, ‘Success’.
21:25:14, ‘idVizServer’, ‘StartService’, ‘Success’.
21:25:15, ‘MetadataService’, ‘StartService’, ‘Success’.
21:25:14, ‘idVizServer’, ‘StartService’, ‘Success’.
21:25:14, ‘DeliveryService’, ‘StartService’, ‘Success’.
21:25:14, ‘SMDService’, ‘StartService’, ‘Success’.
21:25:14, ‘QLSBIService’, ‘StartService’, ‘Success’.
21:25:14, ‘idVizService’, ‘StartService’, ‘Success’.
21:25:14, ‘idVizService’, ‘StartService’, ‘Success’.
21:25:15, ‘HumanTaskService’, ‘StartService’, ‘Success’.
21:25:15, ‘AnnotationService’, ‘StartService’, ‘Success’.
21:25:15, ‘MonitorService’, ‘StartService’, ‘Success’.
21:25:15, ‘AgentService’, ‘StartService’, ‘Success’.
21:25:15, ‘JobService’, ‘StartService’, ‘Success’.
21:25:15, ‘EventService’, ‘StartService’, ‘Success’.
21:25:25, ‘CPS Producer Registration Service’, ‘StartService’, ‘Success’.
21:25:26, ‘Dispatcher’, ‘Start’, ‘Success’.
21:25:31, ”, ”, ‘Success’.
21:25:56, ”, ‘Run’, ‘Run’.
21:25:56, ”, ‘Run’, ‘Run’.
21:25:56, ”, ‘Run’, ‘Run’.
21:25:56, ”, ‘Run’, ‘Run’.
21:25:56, ”, ‘Run’, ‘Run’.